3.3kV -12kV variable speed drives for steel mills
Product Structure
Sinopak MVVFD includes integrated structure and split-type structure based on capacity. The integrated structure is adopted in low capacity MV VFD and the split-type structure is adopted in high capacity MV VFD. In terms of an integrated machine, which is compact in size, phase-transformer, power units, control systems, and power frequency bypass are fully integrated into one cabinet; In terms of a split-type machine, phase-transformer, power units, control systems and power frequency bypass are assembled in separate cabinets in which are combined on the spot.
Technical Parameters
Medium voltage input
|
Voltage range
|
3KV, 3.3KV, 4.16KV, 6KV, 6.6KV, 10KV, 11KV (-20%~+15%)
|
Frequency range
|
50/60 Hz±10%
|
Medium voltage output
|
Output voltage
|
0~Rated voltage
|
Output frequency and accuracy
|
0~50/60 Hz, 0.01 Hz
|
Output waveform
|
Multilevel PWM sin wave, total harmonic distortion (THD) < 4%
|
Performance
|
Efficiency
|
Inversion efficiency at an rated load > 98.5%, overall efficiency (including the transformer) > 97%
|
Power factor
|
Power factor (within the range of speed regulation) > 0.95, power factor (at a rated load) > 0.97
|
Overload capacity
|
110%: long-term stable operation, 120%: 1 minute, 150%: 2 seconds, and 160%: prompt protection
|
Allowable outage duration
|
200 ms (and longer under light load)
|
Mean time between failures
|
> 100,000 hours
|
Control
|
Control mode
|
flux optimization and control with space vector PWM
|
Acceleration/deceleration time
|
1 to 3,600 seconds
|
Switching quantity input/output
|
11-way/10-way
|
Analog input
|
4-way (optional: 0 to 5 V, 4 to 20 mA)
|
Analog output
|
3-way (optional: 0 to 10 V, 4 to 20 mA )
|
Communications
|
RS485 interface, Modbus-based (optional Profibus-DP and Ethernet interfaces)
|
Control power supply
|
Single-phase 220 V AC, 5kVA
|
Excitation control ( dedicated for the synchronous motor)
|
Control mode
|
Automatic excitation control, manual excitation control, multi-stage speed excitation control, and external excitation control for the MVVFD
|
Environment
|
Operating environment
|
Operating in indoor environment without explosive or corrosive gases, conductive dust, or oil fog
|
Operating ambient temperature
|
0℃~+45℃
|
Storage and transportation temperature
|
-40℃ ~+70℃
|
Ambient humidity
|
< 90% (No condensation)
|
Operating altitude
|
Derating required for an altitude greater than 1000 meters
|
Others
|
Protection function
|
Overcurrent, overload, short circuit, three phase current unbalance, immediate electric outage, input/output phase loss, overvoltage, undervoltage, body overheat, transformer overheat, shutdown due to external fault, and power unit auto bypass
|
Cooling mode
|
Forced-air cooling
|
User interface
|
An 10-inch Human Machine Interface
|
Protection grade: IP31
|
IP31
|
|
|
|
|
Product Image
|